Carestream Sign In
Welcome to Carestream.com's communities.
Our customers and partners have access to powerful online communities and tools. Use this overview to discover the best destination for you. Registration and sign-in are required to access these websites.
Vue Cloud Community
Carestream's Vue Cloud Community is your single point of access to the tools you need to diagnose exams, review a patient portfolio or view real-time department performance.
Carestream.com Communities and Tools
Welcome to Carestream.com's communities.
Our customers and partners have access to powerful online communities and tools. Use this overview to discover the best destination for you. Registration and sign-in are required to access these websites.
Vue Cloud Community
Carestream's Vue Cloud Community is your single point of access to the tools you need to diagnose exams, review a patient portfolio or view real-time department performance.
- 特長
- 仕様
- オプション
- サポート
- サイズ
特長
フィルムは、露光のキャリブレーションおよび監視を行うための便利な手段です。
- 大きな面積
- 低コスト、幅広い可用性
- 相対的な線量測定に最適(照射野均一性、装置特性、照射野形状、ポート開口部、MLCなど)
- 適正なキャリブレーションによって、フィルムによる絶対的線量測定が可能(IMRTなどの高線量治療法など)
EDR2の直接露光用途に適した特長
- 幅広い反応範囲
- ほぼ直線的なカーブ
- 強力な耐処理性
仕様
EDR2フィルム-評価用線量反応
正確な線量反応は、現像状態(現像時間、現像温度、プロセッサー、処理薬品)や、濃度測定法(デジタイザ機器やキャリブレーション)、露光モニタ機器など、施設の各要素に依存します。正確な反応関係は、施設ごとの条件に対して測定、確認する必要があります。このフィルムは、「サービス情報No.30(英語)」に記載されている推奨条件で現像する必要があります。
測定方法
フィルムの線量反応は、適切な量のビルドアップや後方散乱体を使用して測定する必要があります。フィルムの反応を測定するための方法については、多数の参考文献で議論されています。参考文献例:
- M. D. C. Evans and L. J. Schreiner, "A simple technique for film dosimetry," Radiother. Oncol. Vol 23, pages 265–267, 1992.
- J. I. Hale, A. T. Kerr, and P. C. Shragge, "Calibration of film for accurate megavoltage photon dosimetry," Med. Dosimetry Vol 19, pages 43–46, 1994.
- Inhwan J. Yeo, C-K Chris Wang, and Sandra E. Burch, "A filtration method for improving film dosimetry in photon radiation therapy," Medical Physics Vol 24, pages 1943–1953, December 1997.
- J. L. Robar and B. G. Clark, "The use of radiographic film for linear accelerator stereotactic radiosurgical dosimetry," Medical Physics Vol 26, pages 2144–2150, 1999.
オプション
その他のEDR2レディパックフィルム |
|||||||||||||||
適切なフィルムを選択するには、用途と対象となる露光範囲を考慮する必要があります。
|
サポート
フィルムは、次に記載されている推奨条件で現像する必要があります: 「サービス情報No.30(英語)」
サイズ
EDR2フィルムは以下の2種類のサイズを用意しています。
- 25.4x30.48cm(10x12インチ)
- 35x43cm
Choose a Region
- Africa
- Asia Pacific
- GCC
- Europe
- Middle East
- North America
- South America
Africa
Saint Helena
Sao Tome and Principe Senegal Seychelles Sierra Leone Somalia South Africa Sub Sahara Africa Sudan Swaziland Tanzania Togo Tunisia Uganda |
Western Sahara
Zambia Zimbabwe |
Asia Pacific
GCC
Europe
Norway
Poland Portugal Romania Russia San Marino Serbia Slovakia Slovenia Spain Sweden Switzerland Tajikistan Turkmenistan |
Ukraine
United Kingdom Uzbekistan |
Middle East
North America
South America
São Cistovão and Nevis
São Vicente and Granadina Suriname Trinidad and Tobago Turk and Caicos Islands Uruguay U.S. Virgin Islands Venezuela Virgin Islands (British) |